Abstract

Abstract Background and purpose Based on the data of patients who measured office BP (OBP) in controlled condition, home BP (HBP), and 24-hour ambulatory BP (24hABP) for diagnosis of hypertension, we developed and validated a diagnostic algorithm for hypertension. Methods Patients who have high BP (≥140/90 mmHg) at the outpatient clinic were referred to measure OBP in controlled condition, HBP and 24hABP. The OBP was measured three times at each visit for 3 days in controlled condition by using a validated oscillometric device. HBP was measured for 7 days in triplicates every morning and evening. The 24hABP was measured on the 8th day. Same study protocol was used for development and validation population. Results In the development of algorithm, 319 patients were recruited and data of 256 patients (51.8±9.7 years, 119 men) with valid HBP and 24hABP measurements were analyzed. In the validation of algorithm, 300 patients were recruited and data of 257 patients (52.4±9.8 years, 126 men) with valid HBP and 24hABP measurements were analyzed. In the development population, the prevalence of masked hypertension was 19.5% (n=50) and most of them (n=47, 94%) was in the range of 130–139/80–89 mmHg. The BP in the range of 130–144/80–94 mmHg was defined as the grey zone of OBP, because prevalence of white-coat hypertension was lowered to 1.6% from 4.3% with threshold of 145/95 mmHg. The diagnostic sensitivity, specificity, positive and negative predictive value of OBP was improved to 97.4%, 76.5, 96.5% and 81.3% after excluding the grey zone of OBP (n=125). The diagnostic agreement between 24hABP and HBP in the grey zone of OBP was 64%. The diagnostic sensitivity, specificity, positive and negative predictive value of HBP were 88.8%, 74.7, 93.5% and 61.5% after excluding the grey zone of HBP (130–134/80–84 mmHg, n=28). Based upon these results, we developed a diagnostic algorithm for hypertension by using on out-of-office BP measurements to improved diagnostic accuracy of hypertension (Figure). In the validation population, the developed algorithm showed similar diagnostic accuracy. Diagnostic algorithm for hypertension Conclusion For accurate diagnosis of hypertension, OBP measurement according to guidelines and 24hABP measurement to grey zone of OBP is preferred. To improve diagnostic accuracy of HBP measurement, 24hABP measurement to grey zone of HBP is required. Acknowledgement/Funding Part of this study was supported by a grand from Dong-A ST Co. Ltd., Seoul, Korea.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.