Abstract

Abstract Background Left atrial appendage occlusion with Watchman device traditionally relies on accurate left atrial appendage (LAA) ostium diameter measurement by 2D or 3D transesophageal echocardiogram (TEE). Alternate methods of ostium measurement including area-derived diameter and perimeter-derived diameter using cardiac computed tomography (CT) have been proposed. Purpose We aim to use CT technology with an advanced medical imaging application to measure LAA ostium perimeter for improved pre-procedural device sizing. Methods We performed a retrospective analysis of 92 patients with atrial fibrillation (Afib) who underwent Watchman implantation with pre-procedural TEE and cardiac CT between May 2015 and December 2018. LAA characteristics including ostial or landing zone perimeter, minimum and maximum diameters were acquired utilizing 3mensio Structural Heart Imaging Program. Proposed Watchman device size was estimated utilizing ostium perimeter by CT and compared to the current standard utilizing ostium diameter by 2D-TEE. Both measurements were then compared to actual implanted Watchman device size which met the P.A.S.S. criteria of position, anchor, size and seal. Results Watchman device sizing based on novel LAA landing zone perimeter size by CT had a very high correlation with the actual implanted Watchman size (Pearson coefficient r=0.94, p<0.001). Traditional TEE based Watchman sizing only had a modest correlation with the implanted Watchman size (Pearson coefficient r=0.66, p<0.001). CT predicted Watchman size had a significantly higher agreement compared to current standard TEE based sizing (93.4% vs 47.8%), inter-rater agreement was very high for CT based Watchman sizing compared to current standard TEE based sizing (Cohen's kappa = 0.91 vs Cohen's kappa = 0.32, p<0.001, p<0.001 respectively). Bland-Altman analysis also showed better correlation with CT based sizing compared to TEE (see Figure 1). Figure 1 Conclusion CT LAA perimeter sizing is superior to the current standard TEE based Watchman sizing. Larger, multi-center studies may be necessary to further validate our results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.