Abstract

The purposes of this study are to investigate ozonation characteristics, to evaluate oestrogenicity and to confirm behaviours of by-products during ozonation of secondary effluent. For the ozonation of secondary effluent, TOC was decreased only 10% when 4 (mgO3/mgC) of ozone consumption per initial TOC. However, UV254 and SUVA was decreased approximately 65% until ozone consumption of 2 (mgO3/mgC). Ozonation was also shown to be very effective for decrease of oestrogenicity in secondary effluent. Bromate ion started to form obviously when the ozone consumption per initial TOC exceeded 2 (mgO3/mgC) and increased while the time of ozonation became longer. From these results, ozone consumption per initial TOC was shown to be an appropriate operation parameter to reduce SUVA effectively and E2 equivalent concentration to less than 0.1 nM without significant formation of bromate ion, and its value was determined to be 2 (mgO3/mgC) in ozonation of secondary effluent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.