Abstract
The true outgassing from surfaces is often masked by the production of gases and pumping within the measuring gauge. Quadrupole mass analysers have been used to measure the outgassing from carefully prepared samples of stainless steel. By using an isolation pressure rise technique coupled to non-evaporable getter pumping, the problem of production of methane by the gauge is overcome and it has been possible to measure the outgassing of methane to very low levels. The specific outgassing rate of methane from 316 L stainless steel is found to be ⩽5×10 −22 mbar l s −1 cm −2. The outgassing of the other gases has been measured using several gauges. The specific outgassing of hydrogen is found to be 4.5×10 −15 mbar l s −1 cm −2 and the total of all other gasses amounted to no more than 10% of this figure. Although the measurements of the other gases are more ambiguous than those for methane, it is concluded that, in all probability, only hydrogen is outgassed from stainless steel.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.