Abstract

Ulnar shortening osteotomy is a well-established treatment for ulnar impaction syndrome. Controversy remains regarding the most effective system to achieve efficient bony union, whilst minimising incidence of complications, particularly hardware irritation. We present outcomes at 2 years using the recently released low profile AO osteotomy system. 32 consecutive patients with significant pain from ulnar impaction syndrome (idiopathic or post-traumatic), without degenerative changes of the distal radio-ulnar joint, were included. Time to union, range of motion, grip strength, pain and complications were recorded. Median time to union was 10.14 weeks (9.27-11.01, 95%CI), with one nonunion. Visual Analogue Pain score, grip strength and range of motion improved significantly. No patient experienced hardware irritation. No plate required removal. Positive ulnar variance was reduced by 3.8 mm (mean). The low profile AO system appears effective in achieving bony union whilst minimising incidence of hardware irritation, at a follow up of 2 years.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.