SU-8 is a photoplastic polymer with a wide range of applications in microtechnology. Cantilevers designed for a commercial Atomic Force Microscope (AFM) were fabricated in SU-8. The mechanical properties of these cantilevers were investigated using two microscale mechanical testing techniques: contact surface profilometer deflection, known as MAT-Test, and static load deflection using a specially designed test machine, the MFT2000. The Young's modulus values from the microscale test methods are approximately 2-3 GPa. These results are compared with results from macroscale tests of 4-5 GPa. The test methods and the results are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.