Abstract
o estimate CRSSs of slip systems in hcp crystals, shear tests of magnesium single crystals were carried out at room temperature. In the shear test, basal slip occurred within shear deformation area, and CRSS of the basal slip was estimated as 0.35MPa. However, specimens for prismatic slip deformed with {101^^-2} twin. The test result shows that CRSS of prismatic slip in magnesium will be more than 90MPa. To estimate CRSS of the prismatic slip precisely, alternate specimens for shear test should be necessary.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Proceedings of the Materials and Mechanics Conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.