Abstract

A procedure for optimum design of a high-power, high-frequency transformer is presented. The procedure is based on both electrical and thermal processes in the power transformer and identifies: (a) the VA-rating of ferrite cores in relation to the operating frequency; (b) the optimum flux density in the core; and (c) the optimum current densities of the windings providing maximum transformer efficiency. Since the transformer is the major contributor to the volume and weight of the power supply, the results of transformer analysis can be used for entire power supply optimization as well. Two high-power, high-frequency transformers are optimally designed, built, and tested. Practical results show good agreement with the theory.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.