Abstract

Before a CRT color display is calibrated, the levels of the brightness and contrast controls should be considered. These levels have different effects on the relationship between the chromaticity coordinates of the red-green-blue (RGB) channels and the voltage applied to the gun as well as on the color gamut. Using three different CRT color displays, we measured both these relationships as well as the color gamut for different combinations of brightness and contrast levels. With respect to the luminance range of the white point provided by each display, the results show that the assumption of constant-channel chromaticity of the RGB channels is more valid at medium- to low-brightness levels in combination with high-contrast levels. In addition, this assumption holds at high contrast and medium- to low-brightness levels, the color gamut being optimized at these combinations of levels, with regard to the size of the triangle of primaries-the maximum luminance of the display white point.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.