Abstract

In PEMFC (proton exchange membrane fuel cell) systems operating in dead-end mode, hydrogen purges are needed to remove accumulated inert gases and liquid water from the anode side of the fuel cell stack. Hydrogen purges were studied using different humidity levels, purge times, and purge triggering criteria. The purged gas volume and composition were accurately measured with fast data acquisition and an advanced experimental set-up. The experiments were done with constant current density with aim of keeping the anode gas recirculation rate constant. Fuel utilization per pass varied as the hydrogen content on the anode side changed. This study demonstrates how the optimized purge strategy changes with a changing humidity level. It also shows that high fuel efficiency (>99%) is easily reached and that with optimized purge strategy a very high fuel efficiency (99.9%) can be reached. It was also shown that concentration polarization due to accumulation of inert gases on the anode side is two times higher than values obtained by theoretical calculations. This result is significant for purge strategy and system design.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.