Abstract

Higher demand for refrigeration systems adversely affects power grids, causing blackouts, increased electricity expenses, and carbon emissions. However, using renewable energy thermally driven refrigeration absorption systems is a promising alternative. The higher initial cost and dependency on local weather, large space area for installation, and complex design are hurdles for the widespread of these systems compared to the conventional vapor compression refrigeration systems. This study uses response surface methodology to model a real vapor absorption machine (VAM) incorporated with the measured data. This VAM is the refrigeration machine of a solar-powered absorption cooling system (SPACS) integrated with thermal energy storage for milk chilling installed and operated in Jaipur (India). The weather data for 2022 is used in performance and productivity analysis in this study. The results show that most of the summer months, the system can produce desired cooling to take down the 1000 l of milk within 3 h as per standards ISO 5708 – 2 II. Moreover, the solar loop still has sufficient driving heat to charge the 1000 l cold storage tank/another milk tank. During winter days, it takes a significant system response time (SRT) to reach the thermal energy storage (TES) up to 95 °C; after that, VAM operates significantly underperforming due to weak solar insolation; even the system cannot provide cooling to the first milking. The system produces monthly cooling energy of up to 2356 kWh in summer and is reduced to 620 kWh during monsoon and winter. The maximum value of the coefficient of performance (COPVAM) is achieved as 0.55 with an average of 0.41–0.46 during summer months whereas 0.34–0.39 during monsoon and winter days. The system's energy efficiency ratio (EER) ranges from 2.5 to 6.5, with an overall average of 4.55, which is far better than the conventional vapor compression refrigeration systems. The LCOE for the SPACS has been estimated to be 0.177 $/kWh, whereas the simple payback period is 12.4 years, and the discounted payback period is 19.7 years.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.