Abstract

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> Open-loop interleaving methods for PFC boost converters operating at the boundary of discontinuous-conduction mode and continuous-conduction mode with a master-slave relationship are analyzed. It is shown that the only method that results in stable operation is the synchronization of the slave converter to the turn-on instant of the master converter, where each converter operates with current-mode control. Effects of mismatched inductances, phase-shift error, switching-frequency limit, and valley switching on the quality of the input current are discussed in detail. </para>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.