Abstract

An 83-year-old man with aortic arch aneurysm underwent zone 0 thoracic endovascular aortic repair (TEVAR) by the chimney graft technique with two supra-aortic arch debranching grafts and developed subacute type A ascending aortic dissection. We performed emergency open conversion with circulatory arrest under deep hypothermia. The tip of the chimney graft (around the sino-tubular junction in the ascending aorta) was stiff, making it difficult to inspect the lumen and perform anastomosis. Deep hypothermic circulatory arrest and cutting the endograft stents to mobilize the graft were necessary for secure anastomosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.