Aiming at the health monitoring of IGBT modules based on the online measurement of junction temperature Tj and the saturated voltage drop VCE in the three-level neutral-point-clamped (3LNPC) inverter, this paper puts forward the idea of creating a suitable monitoring environment to inject monitoring current without affecting the normal operation of the inverter. Based on this method, not only the online monitoring can be performed at different moments, but also the monitoring duration can be selected according to monitoring requirements. Meanwhile, the online monitoring will not distort the load current of the inverter. In this paper, an online monitoring experiment platform has also been designed to realize the monitoring current injection, the saturated voltage drop VCE sampling, and the sampling data transmission. The results of simulation and experiment verify the safety and the non-intervention of the online monitoring process, and the data collected by DSP during monitoring is used to judge whether the bond wires of IGBT module are failed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.