The behavior of the reverse flow ceiling jet against the ventilation flow from 0.58 to 0.87 m/s was investigated in a 1/3 scale model of a wide body aircraft interior. For all tests, strong reverse flow ceiling jets of hot gases were detected well upstream of the fire. The penetration lengths of the reverse flow ceiling jet for the tests agree fairly well with the relation, lr/H = 0.6 [F−5] where F is the fire-crossflow parameter, F = 2gHQ˙/ρcTsAua3. Both the thicknesses of the reverse flow ceiling jet and the smoke layer increased with the fire-crossflow parameter. The thickness of the smoke layer where the smoke flows along the main flow below the reverse flow ceiling jet was almost twice that of the reverse flow ceiling jet. Detailed spatial and time-varying temperatures of the gas in the test section were measured and velocity profiles were also measured using a temperature-compensated hot film.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.