Abstract

The cascade crossflow packed column is an innovative design that offers the separation advantages of countercurrent flow while avoiding flooding limitations. Liquid and gas cross-sectional flow areas and path length in contact with packing may be controlled independently. These features are illustrated by studying the air stripping of methylene chloride (MeCl), 1,2-dichloroethane (1,2-DCA), and methyl ethyl ketone (MEK). Stripping efficiencies in the cascade crossflow column were generally slightly smaller than in countercurrent flow at equal liquid and gas flow rates. However larger gas-to-liquid ratios were possible in crossflow, permitting larger maximum stripping efficiencies to be attained. The experimental mass transfer coefficients were smaller than predicted by the Onda correlation. Modifications to the gas-phase Onda correlation are proposed that reduce the magnitude of the average deviation between experiment and prediction for 40 tests to about 12%. Experimental values of 38 of 40 tests were wi...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.