Abstract

We present a study on lightning-induced voltages on overhead lines produced by tortuous lightning channels, by using a recently developed tool called CiLIV (Andreotti et al. 2015). CiLIV, initially developed for straight and vertical channels, is here extended to account for tortuosity. High-resolution stereoscopic images of six triggered lightning channels have been 3-D digitized and used as input data for CiLIV. The result is that tortuosity, usually ignored in lightning-induced voltage assessment, can instead play a significant role: an attempt is made in characterizing and quantifying these effects. It is shown that, in contrast to other lightning parameters, like channel-base peak current, which are log-normally distributed and generate log-normally distributed induced voltages too, tortuosity generates normally distributed induced voltages. It is also shown that these voltages can deviate up to 23% (relative standard deviation) from the mean value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.