Abstract
The influence of magnetic saturation on maximum torque to current controlled interior permanent magnet synchronous motor drives is discussed in this paper. A maximum torque to current condition that takes into account magnetic saturation and determines the optimal d-axis current is derived. For the implementation of the proposed controller, an experimental procedure is used to adjust its parameters, therefore, the knowledge of the exact model is not required. Selected experimental results are presented to verify the theoretical considerations and to confirm the high performance of the suggested controller.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.