Abstract
This work numerically explores the thermal-hydraulic performance of twisted oval tube with three cross sectioned wire coils including circular, equilateral and square cross sectioned wire coils in turbulent regime. The effects of geometric shape, direction of rotation and the orientations of wire coil's cross section were also investigated. Polyhedral mesh is adopted and water is used as working fluid. The obtained results are compared with those of the twisted oval tube without wire coils. Our results show that using twisted tube and wire coil together can further enhance heat transfer rate and pump consumption while the PEC decreased. Compared with twisted oval tube only, the equilateral cross sectioned wire coil has the best thermal-hydraulic performance. The averaged increase ratio of Nu is 45.92% and the averaged f is 674.86%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.