Abstract

Building integrated photovoltaic (BIPV)-vacuum system is promising for advanced window application due to its ability to reduce heat transfer, control over admitted solar heat and generates environmentally benign electricity. In this work, numerically thermal comfort for an unfurnished room comprising of BIPV-vacuum glazing was evaluated for the United Kingdom (UK) climate. Required parameters to determine thermal comfort, one-dimensional heat transfer model was developed and validated for BIPV-vacuum glazing and results were compared with BIPV-double-pane glazing system. PV cell temperature difference between these two different types of glazing was 24 °C. For the UK climate, BIPV-vacuum glazing offered 26% higher room temperature at clear sunny day compared to BIPV-double system. BIPV–vacuum glazing system provided soothing or comfortable thermal comfort during mid-day period for a clear sunny day at temperate climate. In a combined BIPV-vacuum glazing, it was also predicted that vacuum glass facing external ambient is suitable for the UK climate whilst vacuum glass facing internal room ambient is applicable for Indian climate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.