Abstract This research aims at finding some alternative solutions to the conventional reinforcement of the masonry in areas with low seismic levels, namely the confination with concrete piles and belts, as provided in the Romanian norms in force, replacing the concrete columns with vertical voids in AAC masonry with metal fibre disperse reinforced concrete.For the masonry modules that were initially tested experimentally, numerical tests were performed using the finite element method with the Abaqus program.The experimental results, the theoretical ones and the structural analysis confirm the possibility of using autoclaved aerated concrete (AAC) confined with disperse reinforced concrete in masonry buildings erected in low seismicity areas
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.