Abstract

Most modern refrigerators incorporate heat transfer between the refrigerant in a capillary tube and the refrigerant in a suction line. This heat transfer is achieved by a non-adiabatic capillary tube called a capillary tube-suction line heat exchanger and is supposed to improve the performance of the small vapor compression refrigeration cycle by removing some enthalpy of the refrigerant at the evaporator entrance. To investigate the effects of this heat transfer on the refrigeration cycle, a computer program was developed based on conservation equations of mass, momentum, and energy. The non-adiabatic capillary tube model is based on a homogeneous two-phase flow model. The simulation results show that both the location and length of the heat exchange section influence the coefficient of performance (COP) as well as the cooling capacity. It is noteworthy that the influence was not monotonic; that is, the performance may be deteriorated under certain conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.