At a fully mechanized working face of a coal mine as prototype, we investigated, by simulation, the flow field and dust distribution during the process of its isolation by a curtain of air, using the CFD software, Fluent. The results show that the air curtain installed on the shearer can effectively prevent the dust (especially the respirable dust) from diffusing into the work area of the operator, reducing the dust concentration on the side of the operator and greatly improving his working environment. The field application of the air curtain shows that the dust-isolation effect of an air curtain is quite noticeable. The isolation efficiency for respiratory dust is over 70% and, as well, it has good dust-isolation effect for non-respiratory dust. The air curtain is a useful way to resolve the problem of dust-isolation at a fully mechanized working face. It has a practical background elsewhere with more extensive applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.