A printed circuit heat exchanger (PCHE) is utilized to cool the compressor inlet air to increase the compression efficiency in a liquid air energy storage and liquid natural gas (LNG) coupled system, which can offer large-scale energy storage with significantly improved exergy efficiency and round-trip efficiency. In this work, the effect of pressure of air, incline angle, and hydraulic diameter on the performance of a compressed air–water PCHE with a semicircle cross-section was studied. The results show that PCHE can realize the intermediate cooling of air compression in the liquid air energy storage system, and the pressure variation of air shows a limited effect on the heat transfer of PCHE; however, the hydraulic diameter and the incline angle both affect the heat transfer and the flow resistance of PCHE, and the best incline angle is 15°.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.