Abstract

A new hybrid damper which combines a friction damper and steel strip damper is proposed for improving the seismic performance of structures at multiple levels of ground motion. In order to investigate the combined behavior of the proposed damper, quasi-static cyclic tests were carried out on ten specimens. Experimental results demonstrated that hysteretic response was stable, and multi-phased behavior (i.e., activation of two different kinds of dampers) functioned as intended. However, depending on the type of strip damper applied, the behavior and failure modes showed distinct differences due to rotational motion induced during combined behavior; deformation and energy dissipation capacities were enhanced when a strip damper with adequate out-of-plane stiffness was applied. Furthermore, numerical analysis based on both material strength and expected strength well represented behavioral characteristics of the damper, and dissipated energy was reliably predicted. It is expected that the proposed analytical model can be practically applied to predict the performance of structures strengthened by the hybrid damper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.