Abstract
A comprehensive summary of the effects of pulsed ionizing radiation on the operation of several types of passive surface acoustic wave devices is presented. Three distinct types of malfunction were observed and are discussed in detail. In addition, the effects of neutron and 60Co gamma permanent displacement damage on the operation of a monolithic SAW amplifier are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.