Abstract
Abstract This paper presents two different case studies that highlight the use of reflected light imaging in laser scanning microscopy. In the first case study, the exact location of defects in metal comb test structures were much easier to detect with reflected light imaging than with thermally-induced voltage alteration (TIVA). This case study also shows visible-wavelength TIVA defect localization using a 532-nm laser. A comparison between 532-nm TIVA and conventional 1320-nm TIVA is made to show the resolution improvement with the visible laser. In the second case study, the cause of a linear string of bit failures was localized easily with backside reflected light imaging. It is observed that the indicated sites matched the light-induced voltage alteration signals and the failing cells in the bit map. In both of the case studies, the reflected light images have proved very helpful in the localization and characterization of failing devices or test structures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.