Abstract

Analytical solutions for sizing ideal Forward Osmosis membrane systems are developed for both co-current and counter-current flow configurations. They are integral solutions of the mass balance equations, including the one representing transfer across the membrane. Salt passage is assumed to be zero but allowance is made for concentration polarisation. The solutions presented obviate the need for approximations based upon a log mean driving force which are only mere approximations when there is transfer of mass from one side of the transfer surface to the other. Secondly a comparison between the estimates of areas using a log-mean approximation and the calculated areas using the analytical solution shows that the former will generate significant errors at high recoveries for the case of counter-current flow. Thirdly the potential recovery is also elucidated for various combinations of salinity, flow rate ratios and flow arrangement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.