Abstract

Automatic segmentation of Left Ventricle (LV) is an essential task in the field of computer-aided analysis of cardiac function. In this paper, a simplified pulse coupled neural network (SPCNN) based approach is proposed to segment LV endocardium automatically. Different from the traditional image-driven methods, the SPCNN based approach is independent of the image gray distribution models, which makes it more stable. Firstly, the temporal and spatial characteristics of the cardiac magnetic resonance image are used to extract a region of interest and to locate LV cavity. Then, SPCNN model is iteratively applied with an increasing parameter to segment an optimal cavity. Finally, the endocardium is delineated via several post-processing operations. Quantitative evaluation is performed on the public database provided by MICCAI 2009. Over all studies, all slices, and two phases (end-diastole and end-systole), the average percentage of good contours is 91.02%, the average perpendicular distance is 2.24 mm and the overlapping dice metric is 0.86.These results indicate that the proposed approach possesses high precision and good competitiveness.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.