In this retrospective study, we aimed to examine the effect of applying Dyna computed tomography (CT) on the success rate of adrenal venous sampling (AVS) without adrenocorticotropic hormone stimulation. A total of 100 consecutive patients with primary aldosteronism who underwent AVS between May 2012 and July 2015 were enrolled. In all the cases, Dyna CT was used in AVS to validate catheter position in the right adrenal vein. A selectivity index (cortisoladrenal vein /cortisolinferior vena cava) of ≥2.0 of both adrenal veins were required for successful AVS. Dyna CT indicated misplaced catheters in 16 patients; of these patients, 75% (12/16) eventually had successful right AVS after catheter repositioning. The success rate of initial sampling at the right adrenal vein was 76% (76/100), which increased to 88% (88/100) after Dyna CT was applied (p < 0.001). The most common inadvertently catheterised vessels detected using Dyna CT were the accessory hepatic veins (56.3%, 9/16), followed by the renal capsular veins (37.5%, 6/16). The overall success rate of non-stimulated AVS using Dyna CT was 87% (87/100). Thus, the application of Dyna CT further increased the success rate of non-stimulated AVS.

Highlights

  • We aimed to investigate the effect of applying Dyna computed tomography (CT) on the success rate of adrenal venous sampling (AVS) without adrenocorticotropic hormone (ACTH) stimulation

  • AVS is currently considered as the gold standard for differentiating between unilateral and bilateral hyperaldosteronism[10]

  • The reliability of the technical performance of AVS is crucial for avoiding repeated AVS procedures

Read more

Summary

Introduction

We aimed to investigate the effect of applying Dyna CT on the success rate of adrenal venous sampling (AVS) without adrenocorticotropic hormone (ACTH) stimulation. Dyna CT was conducted to confirm the catheter position in the right adrenal vein in all cases. The success rate of initial sampling in the right adrenal vein was 76% (76/100), which increased to 88% (88/100) after Dyna CT and on-site re-sampling (p < 0.001; Fig. 2).

Objectives
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.