Abstract

In this study, the progressive collapse potential of a 10-storey concrete frame structure was investigated using nonlinear static analysis. 15 different cases were considered and their performances were compared with each other. From the nonlinear static analysis results, most of longitudinal beams in upper floors and slabs above the failure column would collapse as the results of removing an exterior column, no beams and slabs would collapse when an interior column at ground floor was removed, and only the short-span beams in superstructure would collapse when an interior column in upper floors was removed. Tie force reinforcement along floors and beams of edge span can be used to avoid the progressive failure of floors, after failure of particular column.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.