In recent years, concrete-filled steel tube (CFST) was developed and used extensively in civil engineering in China. In this paper, the method for stability analysis of long-span CFST arch bridge was introduced. Based on Jingyang River Bridge in Hubei province of China and finite element method, the spatial model was set up. Both linear and nonlinear stability of long-span CFST arch bridge in construction process were analyzed. The result indicated the influence of geometrical nonlinearity was small and the influence of material nonlinearity was evident. So, for analyzing the stability of long-span CFST arch bridge, the influence of geometrical nonlinearity and material nonlinearity must be considered at the same time. The results of paper were used to provide the basis for the construction control of the bridge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.