Abstract

New codes have recently introduced seismic detailing for new structures. However, there are still older reinforced concrete (RC) structures without proper ductile detailing for earthquake resistance in seismic-prone areas. These structures are further impacted by the corrosion of their embedded reinforcing bars, which further reduces the strength and ductility under axial cyclic loading. This paper summarises the results of an experimental investigation performed on low-strength short RC columns, with different confinement configurations, subject to varying degrees of corrosion to investigate their structural responses to axial cyclic loading. The experiment was conducted on 30 short RC columns (square and circular) with three levels of confinement and steel reinforcement corrosion loss ranging from 0% to ∼ 30% subjected to cyclic compressive loading. The test results show that corrosion and inadequate confinements have a significant negative impact on the structural responses of corroded columns.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.