Abstract

We compare bridge voltage response measurements to ac magnetic fields from a giant magnetoresistive sensor with noise measurements on the same sensor. The small-signal response (for applied ac magnetic fields between 0.1 mOe rms and 30 mOe) is much less than is the slope of a dc voltage versus field curve, because of hysteretic effects. Noise statistics are used to estimate the size and number of the sites at which domain realignments occur near the response peak. Similar estimates are made by using fine-structure on the ac response curve. For ac fields of about 0.3 mOe rms, sharp spikes appear in the field-dependent response, giving rise to large harmonic distortion, varying in an irregular way with the ac amplitude. Domain sizes are estimated for the regions, giving these nonlinear response spikes, and for the domains, giving the magnetic noise, and a comparison based on a fluctuation-dissipation relation of the noise, and the response shows the importance of hysteresis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.