Abstract
Membrane based non-dispersive solvent extraction (NDSX) of Nd(III) from aqueous nitric acid medium was carried out using a commercial liquid-liquid extraction system consisting of an extra-flow hollow fiber module with about 10,000 microporous hydrophobic polypropylene capillaries with an effective surface area of 1.4 m2. The NDSX operation was carried out by pumping about 1 g/L Nd(III) solutions at a fixed nitric acid concentration of 3.57 M through the tube side and organic solvent (tetra-n-octyl-3-oxapentane-diamide (TODGA) in normal paraffin hydrocarbon (NPH)) through the shell side of the hollow fiber capillaries. NDSX studies were performed under different hydrodynamic conditions and the overall mass transfer was evaluated under counter-current flow conditions. Conditions for quantitative extraction and stripping were also identified. Reproducibility of the results from multiple runs was found to be excellent after five different identical runs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.