Abstract

A robust and simple sensing scheme utilizing a Mid-Infrared Light Emitting Diode (MIR-LED) and based on Differential Mode Excitation Photoacoustic (DME-PA) spectroscopy is presented. A MIR-LED light source in combination with optical correlation is used for simplicity and compactness. The sensing setup takes advantage of the non-linearity in the excitation of various acoustic modes in a cylindrical resonant photoacoustic cell to provide a high selectivity. The sensing device is tested using methane and hydrocarbon mixtures (propane, butane). The obtained limit of detection for methane is 25 ppm m−1. Using the presented DME-PA scheme, the derived gas concentration is hardly affected neither by intensity fluctuations of the light source nor by any microphone or electronics drifts. Furthermore, a considerably improved selectivity is obtained compared to conventional Non-Dispersive Infrared (NDIR) techniques.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.