Abstract

Non-axisymmetric simulations of the current quench phase of ITER disruptions are key to predict asymmetric forces acting into the ITER wall. We present for the first time such simulations for ITER mitigated disruptions at realistic Lundquist numbers. For these strongly mitigated disruptions, we find that the safety factor remains above 2 and the maximal integral horizontal forces remain below 1 MN. The maximal integral vertical force is found to be 13 MN and arises in a time scale given by the resistive wall time as expected from theoretical considerations. In this respect, the vertical force arises after the plasma current has completely decayed, showing the importance of continuing the simulations also in the absence of plasma current. We conclude that the horizontal wall force rotation is not a concern for these strongly mitigated disruptions in ITER, since when the wall forces form, there are no remaining sources of rotation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.