Abstract

BackgroundECG detection of ST-segment elevation myocardial infarction (STEMI) in the presence of left bundle-branch block (LBBB) is challenging due to ST deviation from the altered conduction. The purpose of this study was to introduce a new algorithm for STEMI detection in LBBB and compare the performance to three existing algorithms. MethodsSource data of the study group (143 with acute MI and 239 controls) comes from multiple sources. ECGs were selected by computer interpretation of LBBB. Acute MI reference was hospital discharge diagnosis. Automated measurements came from the Philips DXL algorithm. Three existing algorithms were compared, (1) Sgarbossa criteria, (2) Selvester 10% RS criteria and (3) Smith 25% S-wave criteria. The new algorithm uses an ST threshold based on QRS area. All algorithms share the concordant ST elevation and anterior ST depression criteria from the Sgarbossa score. The difference is in the threshold for discordant ST elevation. The Sgarbossa, Selvester, Smith and Philips discordant ST elevation criteria are (1) ST elevation ≥500μV, (2) ST elevation ≥10% of |S|-|R| plus STEMI limits, (3) ST elevation ≥25% of the S-wave amplitude and (4) ST elevation ≥100μV+1050μV/Ash * QRS area. The Smith S-wave and Philips QRS area criteria were tested using both a single and 2 lead requirement. Algorithm performance was measured by sensitivity, specificity, and positive likelihood ratio (LR+). ResultsAlgorithm performance can be organized in bands of similar sensitivity and specificity ranging from Sgarbossa score ≥3 with the lowest sensitivity and highest specificity, 13.3% and 97.9%, to the Selvester 10% rule with the highest sensitivity and lower specificity of 30.1% and 93.2%. The Smith S-wave and Philips QRS area algorithms were in the middle band with sensitivity and specificity of (20.3%, 94.9%) and (23.8%, 95.8%) respectively. ConclusionAs can be seen from the difference between Sgarbossa score ≥3 and other algorithms for STEMI in LBBB, a discordant ST elevation criterion improves the sensitivity for detection but also results in a drop in specificity. For applications of automated STEMI detection that require higher sensitivity, the Selvester algorithm is better. For applications that require a low false positive rate such as relying on the algorithm for pre-hospital activation of cardiac catheterization laboratory for urgent PCI, it may be better to use the 2 lead Philips QRS area or Smith 25% S-wave algorithm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.