Abstract
Although the region of the Tokamak Fusion Test Reactor (TFTR) vacuum vessel wall which is susceptible to damage by neutral beam strike is armored with a mosaic of TiC-clad POCO graphite tiles, at power deposition levels above 2.5 kW/cm2 the armor surface temperature exceeds 1200 °C within 250 ms, and itself becomes susceptible to damage. In order to protect the wall armor, a neutral beam interlock system based on infrared pyrometry measurement of the armor surface temperature was installed on TFTR. For each beamline, a three-fiber-optic telescope views three areas of ∼30 cm diameter centered on the armor hot spots for the three ion sources. Each signal is fiber-optic coupled to a remote 900-nm pyrometer which feeds analog signals to the neutral beam interrupt circuits. The pyrometer interlock system is designed to interrupt each of the 12 ion sources independently within 10 ms of the temperature exceeding a threshold which can be set in the range of 500–2300 °C. A description of the pyrometer interlock system and its performance will be presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.