Abstract

Approximate expressions are discussed which are applicable for acoustic quantities in the vicinity of a plane piston source of ultrasound which radiates into an absorbing medium. A particularly useful approach for nearfield calculations combines an expression valid near the axis with another, given by Pierce [Acoustics, An Introduction to Its Physical Principles and Applications (McGraw-Hill, New York, 1981), Chap. 5], which is valid elsewhere. This approach gives reasonable accuracy at relatively low computational cost. Computed plots are presented, showing spatial distributions of the square of the pressure amplitude. Most of the plots are for a source diameter of 1.2 cm, a frequency of 3 MHz, and an absorption coefficient of 0.15 Np/cm; these are representative of conditions for medical applications of ultrasound.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.