Abstract
BackgroundGlaucoma drainage implants have been used with increasing frequency for the management of glaucoma. Patients who are candidates for glaucoma drainage devices often have more severe disease and are at risk of vision loss with post-operative elevations in intraocular pressure (IOP). One post-operative complication that can result in IOP elevation after glaucoma drainage device implantation is occlusion of the tube lumen.Case presentationHere, we present a novel case of tube occlusion by the anterior capsule in a patient who underwent combined phacoemulsification and Ahmed glaucoma valve implantation. The tube occlusion was successfully managed with Nd:YAG capsulotomy with immediate IOP lowering.ConclusionsWhile there have been previous reports of occlusion of the tube lumen by vitreous, iris, blood and fibrin, to our knowledge this is the first report of tube occlusion by the anterior lens capsule and the first report to describe its successful management.
Highlights
Glaucoma drainage implants have been used with increasing frequency for the management of glaucoma
While there have been previous reports of occlusion of the tube lumen by vitreous, iris, blood and fibrin, to our knowledge this is the first report of tube occlusion by the anterior lens capsule and the first report to describe its successful management
Glaucoma drainage implants are often reserved for patients with glaucoma that is refractory to medical management and who are at risk for vision loss with post-operative intraocular pressure (IOP) elevations [2]
Summary
Glaucoma drainage implants have been used with increasing frequency for the management of glaucoma. Conclusions: While there have been previous reports of occlusion of the tube lumen by vitreous, iris, blood and fibrin, to our knowledge this is the first report of tube occlusion by the anterior lens capsule and the first report to describe its successful management. One potential post-operative complication that can result in persistently elevated IOP after glaucoma drainage device implantation is tube occlusion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.