Abstract

In the present work, natural convection heat transfer from discrete heat sources mounted in rectangular enclosure using liquid coolant is investigated. Heat transfer from discrete heaters is non-uniform and should be accounted for by applying the averaging techniques. The averaged two-dimensional governing equations along with the standard k-e model and wall function are solved using the SIMPLE algorithm. The effects of the e cooling fluid type water and dielectrics oil, the different heat flux and time on heat transfer are investigated. The results are compared with experimental measurements. Results show that water gives a good cooling effect compared with dielectrics oil. Maximum heat transfer occurs at the heater leading and side edges. The heater surface temperature is highest at the top-row heaters. Results show also good agreement between the theoretical and experimental measurements.

Highlights

Read more

Summary

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.