Abstract

Sensitive detection of tumor biomarkers is of great significance for early cancer diagnosis, treatment evaluation, and recurrence monitoring. Development of convenient electrochemiluminescence (ECL) immunosensor using dissolved oxygen (O2) as an endogenous co-reactant of luminol combined with efficient nanocatalysts to boost ECL signal in neutral media is highly desirable. Herein, sensitive detection of tumor biomarker using ECL of luminal-O2 enhanced by confinement of nitrogen-doped graphene quantum dots (N-GQDs) and platinum nanoparticles (PtNPs) on nanochannel array was demonstrated. A high-density nanochannel array-modified electrode was achieved by rapidly growing an amino-functionalizedvertically-ordered mesoporous silica film (NH2-VMSF) on the inexpensive and readily available indium tin oxide (ITO) electrode. Through simple electrodeposition, N-GQDs were confined and PtNPs were in-situ synthesized in nanochannels of NH2-VMSF. These confined nanocomposites catalyzed the electroreduction of O2 at negative potentials to generate a large amount of reactive oxygen species (ROS) and facilitated luminol oxidation, enhancing the ECL signal of luminol by 25 times. Two immunosensors were fabricated after covalent immobilization of the recognition antibody of carbohydrate antigen 199 (CA199) or carbohydrate antigen 125 (CA125) on the outer surface of the NH2-VMSF and blocking of non-specific sites. When tumor biomarkers bind to the corresponding antibodies on the recognition interface, the formed immunocomplex hindered the diffusion of luminol to the underlying electrode, resulting in a decrease in the ECL signal and sensitive detection of tumor biomarker. The constructed CA199 immunosensor exhibited a linear detection range for CA199 from 0.5 mU mL−1 to 50 U mL−1, with a detection limit (DL) of 0.03 mU mL−1. For CA125 detection, linear detection ranged from 0.5 mU mL−1 to 500 U mL−1, with a DL of 0.005 mU mL−1. The fabricated immunosensors demonstrated good selectivity and high reproducibility. This study provides great potential for the development of efficient luminol ECL systems in neutral media and expands the biological application in sensitive detection of tumor biomarker.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.