Abstract
A measurement of the thermoelectric property of conductive ceramics by multi-scan method was developed. The conductive boride composite ceramics (104 S) with a size of 2×3×15mm was used in this experiment. The electorical conductivity and Seebeck coefficient at high temperature by multi-scan method were carried out in an electric furnace in an argon gas atmosphere at room temperature to 1073K. A rapid and accurate measurement of the Seebeck coefficient was performed by multi-scan method. The time needed for each measurement was less than a few fiftys of seconds, significantly shorter with accuracy than for a conventional do method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.