Abstract

A multi-story shear wall has often discrete joints without cotter reinforcements at the vertical joints between the wall panels and the surrounding cast-in-place columns. The sliding displacement in joints which display a resistance mechanism different from that of cast-in-place shear wall is expected to occur. In order to investigate the effect of resistant of joints on earthquake resistant performance, a shear failure type experiment was performed on seven multi-story precast concrete walls having a variety of cotter and joint reinforcement ratio at joints. Based on the results of this experiment, the resistance mechanism of a precast concrete multi-story shear wall and a design formula of the slip strength of horizontal joints are proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.