Abstract

This paper describes a new developed wooden sliding panel wall inserted in wooden frame. In-plane shear tests for two types of these panel walls were carried out compared with the typical plywood sheathed wall. The main results are as follows. The rigidity and strength of the new developed walls are about 20% and 50% of those of contemporary bearing walls under the horizontal deformation of 0.05 rad. Although, beyond this deformation, the rigidity and strength of new developed walls gradually improve and withstand large load.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.