Abstract
We describe a method for analyzing the harmonics components of the air-gap magnetic flux density distribution of doubly-fed generators that takes into consideration the influence of the circumference slot arrangement and winding pattern. The proposed method is based on an analytical equation of the permeance and the magnetomotive force (mmf) distributions. This method is applied to analyze quantitatively the harmonic components of the air-gap magnetic flux density distributions of a doubly-fed generator under different driving conditions. The analytical results obtained using the proposed method are in agreement with those of finite element magnetic field analysis (FEA). Thus, this method is shown to be an appropriate and useful method for quantitatively estimating magnetic flux density for doubly-fed generator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.