Abstract
Recently, several immune network information models are proposed, and they are applied to process diagnosis as well as sensor fault diagnosis of cement process by Prof. Ishida. In this paper, a simple network model for the water supply system of waterworks is diagnosed using this immune network information model, and it is tried to find the cause of a sensor fault diagnosis and process faults diagnosis (water leak etc.). Through some numerical examples the effectiveness and applicability of immune network information model is shown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Society of Materials Science, Japan
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.