Abstract
Permanent implantation of electrodes for prosthetic control is now possible using an osseointegrated implant as a long-term stable communication interface (e-OPRA). The number of myoelectric sites to host such electrodes can be increased by Targeted Muscle Reinnervation (TMR). Traditionally, patients need to wait several months before the TMR signals are strong enough to be recorded by electrodes placed over the skin. In this study, we report the evolution of the TMR myoelectric signals recorded from two subjects via implanted electrodes using e-OPRA, and monitored for up to 48 weeks after surgery. The signals were analyzed with regard to amplitude (signal-to-noise ratio), independence (cross-correlation) and myoelectric pattern recognition (classification accuracy). TMR signals appeared at the first follow-up, one month post-surgery, and developed around 20 dB by the last. Cross-correlation between signals decreased over time and converged to a few percentage points. Classification accuracies were over 97% by the last follow up. These preliminary results suggest that implanted electrodes via the e-OPRA interface allow for an earlier and more effective use of motor signals from TMR sites compared to conventional skin surface electrodes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.