Abstract
Twenty patients with congenital complete heart block (CHB) were monitored with ECG tape recordings while awake and asleep. Episodes of marked ventricular slowing during sleep (R-R greater than 3000 msec., i.e. less than 20 beats/min) were noted in 35% (7/20). Most of these sudden R-R prolongations were 2:1 or 3:1 exit block of the junctional focus. Atrial and ventricular rate changes were mostly concordant in 2/3 but the remainder demonstrated fixed ventricular rates while atrial rates varied normally, suggesting a "sick" or "lazy" junctional focus. Other arrhythmias were found in 60% (12/20), including several types of rhythms in three patients. One child with previously unsuspected superimposed multiple arrhythmias later had a syncopal episode despite proven supra-Hisian block. The multiple patterns of atrial and ventricular rate changes found indicate complex feedback mechanisms, suggesting that congenital CHB is not a single entity. Since a significant number of patients demonstrated one or another of these unexpected and potentially hazardous findings, we recommend that congenital block patients be carefully studied, including Holter monitoring done on a regular basis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.